Technical Parameters:
Model | 101-0A/101-0AB | 101-1A/101-1AB | 101-2A/101-2AB | 101-3A/101-3AB | |||
202-0A/202-0AB | 202-1A/202-1AB | 202-2A/202-2AB | 202-3A/202-3AB | ||||
Cycle Mode | 101 means Forced convection;202 means Natural convection | ||||||
Function | Temp. Range | RT+10-250℃ | |||||
Temp. Resolution Ratio | 0.1℃ | ||||||
Temp. Motion | ±1℃ | ||||||
Temp. Uniformity | 101 model: ±2.5% , 202 model: ±3.5% | ||||||
Structure | Inner Chamber | B model:High quality stainless steel; without B model:High strength galvanized sheet | |||||
Outer Shell | Cold rolling steel electrostatic spraying exterior | ||||||
Insulation layer | High quality rock wool board(with CE) | ||||||
Heater | 101 model with Stainless steel electric heating tube; 202 model with Nickel chromium alloy heating wire | ||||||
Power rating | 1.2kW | 1.6kW | 2.3kW | 3.0kW | |||
Exhaust hole | Φ35mm top(with function of test hole) | ||||||
Controller | Temp. control mode | Two temperature section PID intelligent | |||||
Temp. setting mode | Touch button setting | ||||||
Temp. display mode | LED Digital display | ||||||
Timer | 0-9999min(with timing wait function) | ||||||
Operation function | Fixed temperature operation, timing function,auto stop. | ||||||
Additional function | Sensor deviation correction, temperature overshoot self-tuning, internal parameter locking, power-off parameter memory | ||||||
Sensor | PT100 | ||||||
Safety device | Over temperature sound-light alarm | ||||||
Specification | Inner Chamber size(W*L*H)(mm) | 350*350*350 | 450*350*450 | 550*450*550 | 600*500*750 | ||
Exterior size (W*L*H)(mm) | 652*472*587 | 752*472*687 | 852*572*786 | 902*622*986 | |||
Packing size (W*L*H)(mm) | 745*605*745 | 845*605*850 | 945*705*950 | 955*755*1150 | |||
Volume | 43L | 71L | 136L | 225L | |||
Shelf number | 9 | 13 | 17 | 25 | |||
Load per rack | 15kg | ||||||
Shelf space | 25mm | ||||||
(50/60HZ)Current rating | AC220V/5.5A | AC220V/7.3A | AC220V/9.1A | AC220V/13.6A | |||
NW/GW (kg) | 40/46 | 45/50 | 62/68 | 77/96 | |||
Accessory | Shelf | 2 | |||||
Shelf frame | 4 | ||||||
optional accessories | Shelves |
Features:
1. Horizontal forced air type, high space utilization and good temperature uniformity.
2. 101: Forced fan cooling intake structure, the maximum working temperature <50 ℃, the fan long-term longevity operation.
3. 202: Classical natural convection drying method.
4. New anti-hot handle.
Technical Parameters:
Model | 101-0A/101-0AB | 101-1A/101-1AB | 101-2A/101-2AB | 101-3A/101-3AB | |||
202-0A/202-0AB | 202-1A/202-1AB | 202-2A/202-2AB | 202-3A/202-3AB | ||||
Cycle Mode | 101 means Forced convection;202 means Natural convection | ||||||
Function | Temp. Range | RT+10-250℃ | |||||
Temp. Resolution Ratio | 0.1℃ | ||||||
Temp. Motion | ±1℃ | ||||||
Temp. Uniformity | 101 model: ±2.5% , 202 model: ±3.5% | ||||||
Structure | Inner Chamber | B model:High quality stainless steel; without B model:High strength galvanized sheet | |||||
Outer Shell | Cold rolling steel electrostatic spraying exterior | ||||||
Insulation layer | High quality rock wool board(with CE) | ||||||
Heater | 101 model with Stainless steel electric heating tube; 202 model with Nickel chromium alloy heating wire | ||||||
Power rating | 1.2kW | 1.6kW | 2.3kW | 3.0kW | |||
Exhaust hole | Φ35mm top(with function of test hole) | ||||||
Controller | Temp. control mode | Two temperature section PID intelligent | |||||
Temp. setting mode | Touch button setting | ||||||
Temp. display mode | LED Digital display | ||||||
Timer | 0-9999min(with timing wait function) | ||||||
Operation function | Fixed temperature operation, timing function,auto stop. | ||||||
Additional function | Sensor deviation correction, temperature overshoot self-tuning, internal parameter locking, power-off parameter memory | ||||||
Sensor | PT100 | ||||||
Safety device | Over temperature sound-light alarm | ||||||
Specification | Inner Chamber size(W*L*H)(mm) | 350*350*350 | 450*350*450 | 550*450*550 | 600*500*750 | ||
Exterior size (W*L*H)(mm) | 652*472*587 | 752*472*687 | 852*572*786 | 902*622*986 | |||
Packing size (W*L*H)(mm) | 745*605*745 | 845*605*850 | 945*705*950 | 955*755*1150 | |||
Volume | 43L | 71L | 136L | 225L | |||
Shelf number | 9 | 13 | 17 | 25 | |||
Load per rack | 15kg | ||||||
Shelf space | 25mm | ||||||
(50/60HZ)Current rating | AC220V/5.5A | AC220V/7.3A | AC220V/9.1A | AC220V/13.6A | |||
NW/GW (kg) | 40/46 | 45/50 | 62/68 | 77/96 | |||
Accessory | Shelf | 2 | |||||
Shelf frame | 4 | ||||||
optional accessories | Shelves |